Oral Fluid Testing for Pertussis, England and Wales, June 2007–August 2009
Emerging Infectious Diseases ·
- DOI
- 10.3201/eid2006.131069
- PMID
- —
- PMCID
- —
- OpenAlex
- W2082403900
- Integrity status
- No known notices
- Study design
- Journal article
- Publisher
- Centers for Disease Control and Prevention (CDC)
- Article type
- journal-article
The abstract presents oral fluid testing as a noninvasive surveillance tool that may improve understanding of pertussis epidemiology and inform vaccination-strategy decisions.
Structured evidence summary
Research question
The study evaluated whether oral fluid testing could improve laboratory confirmation of notified, clinically diagnosed pertussis cases that had not been confirmed by established methods.
Study design
This was a pilot evaluation of oral fluid testing used during routine follow-up in England and Wales from June 2007 through August 2009.
Population and setting
The setting was pertussis surveillance in England and Wales. The evaluated group comprised notified, nonconfirmed, clinically diagnosed cases, including children and adults.
Main findings
Established laboratory methods confirmed 1,852 cases, while oral fluid testing confirmed an additional 591 cases. Oral fluid testing increased laboratory ascertainment by 32% overall, with the largest increase among children aged 5–9 years; cases identified by this method were least likely to have been hospitalized.
Public-health relevance
The abstract presents oral fluid testing as a noninvasive surveillance tool that may improve understanding of pertussis epidemiology and inform vaccination-strategy decisions.
Important limitations
The supplied evidence does not state study limitations or provide enough methodological detail for decision-grade assessment. This summary is therefore limited to the supplied single-article abstract and metadata and requires review of the original paper.
GIDS interpretation
The article provides context for how an oral fluid testing approach may improve detection of less severe pertussis cases within surveillance. It should not be interpreted as confirmation of a current surveillance signal.
Related GIDS surveillance
Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.
Evidence relationships
- Disease Pertussis
- Topic Surveillance
- Pathogen type Bacterium
- Study setting The setting was pertussis surveillance in England and Wales. The evaluated group comprised notified, nonconfirmed, clinically diagnosed cases, including children and adults.
- Pathogen Bordetella pertussis
- Study design Journal article

