Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesEbolaHemorrhagic Fever

Evaluation of a point-of-care blood test for identification of Ebola virus disease at Ebola holding units, Western Area, Sierra Leone, January to February 2015

Eurosurveillance ·

N F Walker, C S Brown, D Youkee, P Baker, N Williams, A Kalawa, K Russell, A F Samba, N Bentley, F Koroma, M B King, B E Parker, M Thompson, T Boyles, B Healey, B Kargbo, D Bash-Taqi, A J Simpson, A Kamara, T B Kamara, M Lado, O Johnson, T Brooks

DOI
10.2807/1560-7917.es2015.20.12.21073
PMID
25846490
PMCID
—
OpenAlex
W2419258995
Integrity status
No known notices
Study design
Journal article
Publisher
European Centre for Disease Control and Prevention (ECDC)
Article type
journal-article

The findings suggest that the evaluated rapid test could function as a screening tool to help rule out cases and accelerate identification during outbreaks.

01

Structured evidence summary

Research question

The study assessed the diagnostic accuracy of a bedside rapid diagnostic antigen test for identifying Ebola virus disease relative to RT-PCR.

Study design

This is an operational evaluation assessing diagnostic accuracy among enrolled participants in a field setting.

Population and setting

The evaluation took place at Ebola holding units located in the Western Area of Sierra Leone, enrolling suspected cases.

Main findings

The antigen test achieved a sensitivity of 100% and a specificity of 96.6% when evaluated against RT-PCR among the enrolled group.

Public-health relevance

The findings suggest that the evaluated rapid test could function as a screening tool to help rule out cases and accelerate identification during outbreaks.

Important limitations

This summary is limited to the supplied single-article abstract and metadata, and decision-grade interpretation requires consulting the original paper.

GIDS interpretation

This literature record details field diagnostics for Ebola virus disease in Sierra Leone, providing contextual information on point-of-care testing technology without establishing a live surveillance connection.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease Hemorrhagic Fever
  • Disease Ebola
  • Topic Diagnostics
  • Topic Outbreak investigation
  • Related Diagnostics
  • Pathogen type Virus
  • Location Sierra Leone
  • Study setting The evaluation took place at Ebola holding units located in the Western Area of Sierra Leone, enrolling suspected cases.
  • Pathogen Zaire ebolavirus
  • Study design Journal article