Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesCOVID-19

SARS-CoV-2 samples may escape detection because of a single point mutation in the N gene

Eurosurveillance ·

Katharina Ziegler, Philipp Steininger, Renate Ziegler, Jörg Steinmann, Klaus Korn, Armin Ensser

DOI
10.2807/1560-7917.es.2020.25.39.2001650
PMID
33006300
PMCID
PMC7531073
OpenAlex
W3090205764
Integrity status
No known notices
Study design
Journal article
Publisher
European Centre for Disease Control and Prevention (ECDC)
Article type
journal-article

The result highlights that reliance on a single essential genomic region in diagnostic tests may permit missed detection, informing assay design rather than outbreak scope.

01

Structured evidence summary

Research question

The work examined whether a specific single nucleotide change in the SARS-CoV-2 nucleoprotein gene can reduce detection by a common commercial diagnostic test.

Study design

A journal article reported identification of a SNP in a patient sample and its effect on a commercial assay, with reference to a public sequence database.

Population and setting

The initial observation arose from a patient sample, and sequence prevalence was assessed using the EpiCoV database; Romania is linked as a country topic.

Main findings

A point mutation in the N gene disrupted one probe in a widely used assay, though the virus remained detectable by a second probe. About 0.2% of EpiCoV isolates carried the change, supporting use of two independent targets for dependable testing.

Public-health relevance

The result highlights that reliance on a single essential genomic region in diagnostic tests may permit missed detection, informing assay design rather than outbreak scope.

Important limitations

This summary is limited to the supplied single-article abstract/metadata and requires the original paper for decision-grade interpretation.

GIDS interpretation

The article is discoverable through classifiers linking it to SARS, COVID-19, diagnostics, and Romania, but no live surveillance signal is connected here.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease COVID-19
  • Topic Diagnostics
  • Topic Outbreak investigation
  • Topic Travel medicine
  • Related Diagnostics
  • Pathogen type Virus
  • Location Romania
  • Study setting The initial observation arose from a patient sample, and sequence prevalence was assessed using the EpiCoV database; Romania is linked as a country topic.
  • Pathogen SARS-CoV-2
  • Study design Journal article