Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesRift Valley fever

Development and validation of a pen side test for Rift Valley fever

PLOS Neglected Tropical Diseases ·

Catherine Cêtre-Sossah, Aurélie Pédarrieu, Mikael Juremalm, Petrus Jansen Van Vuren, Alejandro Brun, Ahmed Bezeid Ould EL Mamy, Jean-Michel Héraud, Claudia Filippone, Jean-Pierre Ravalohery, Hassan Chaabihi, Emmanuel Albina, Laure Dommergues, Janusz Paweska, Eric Cardinale

DOI
10.1371/journal.pntd.0007700
PMID
31509527
PMCID
PMC6738586
OpenAlex
W2972911291
Integrity status
No known notices
Study design
Journal article
Publisher
Public Library of Science (PLoS)
Article type
journal-article

The abstract states the assay needs no specialized reagents or laboratory equipment and could serve as a first-line tool for on-site RVFV detection in resource-poor diagnostic territories, while noting staff training is required.

01

Structured evidence summary

Research question

The supplied evidence indicates the work addressed creating and assessing a rapid pen-side immunochromatographic assay to detect Rift Valley fever virus nucleoprotein for on-site diagnosis during suspected outbreaks.

Study design

The supplied abstract describes development of a lateral flow strip test and evaluation of its diagnostic performance using reference virus isolates from varied hosts and regions plus known negative sera, without reporting a prospective clinical or field-outbreak enrollment design.

Population and setting

The evaluated materials comprised reference stocks of RVFV from different hosts and geographic regions mimicking clinical specimens and known RVF-negative serum samples, rather than a described human or animal cohort in a named setting.

Main findings

The reported evaluation showed high diagnostic accuracy for the strip test, with complete detection among positive reference samples and near-complete specificity among negatives, and no observed cross-reactivity with viruses from different genera.

Public-health relevance

The abstract states the assay needs no specialized reagents or laboratory equipment and could serve as a first-line tool for on-site RVFV detection in resource-poor diagnostic territories, while noting staff training is required.

Important limitations

The summary is limited to the supplied single-article abstract and metadata and requires the original paper for decision-grade interpretation; the abstract itself notes only that staff require training and does not enumerate formal study limitations.

GIDS interpretation

The supplied metadata classifies the article under Rift Valley fever and topics including diagnostics, One Health, and outbreak investigation, which supports discoverability of the test-development work in those contexts without linking it to any live surveillance signal.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease Rift Valley fever
  • Topic Diagnostics
  • Topic One Health
  • Topic Outbreak investigation
  • Related Diagnostics
  • Pathogen type Virus
  • Study setting The evaluated materials comprised reference stocks of RVFV from different hosts and geographic regions mimicking clinical specimens and known RVF-negative serum samples, rather than a described human or animal cohort in a named setting.
  • Study design Journal article