Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesDengueChikungunya

A rapid multiplex platform for simultaneous detection of chikungunya virus, dengue virus, and dengue serotyping based on isothermal amplification and lateral flow dipsticks

Infectious Diseases of Poverty ·

Gaowen Liu, Xinlin Wu, Yingchao Chang, Mengyuan Zheng, Li Liu, Xueshan Xia, Yue Feng

DOI
10.1186/s40249-026-01450-9
PMID
—
PMCID
—
OpenAlex
W7160656919
Integrity status
No known notices
Study design
Journal article
Publisher
Springer Science and Business Media LLC
Article type
journal-article

The platform offers potential utility for point-of-care testing and outbreak surveillance in resource-limited settings.

01

Structured evidence summary

Research question

The study evaluated a duplex reverse transcription multi-enzyme isothermal amplification assay paired with lateral flow dipsticks to simultaneously detect chikungunya and dengue viruses and perform dengue serotyping.

Study design

Methodological validation, clinical validation using serum samples from suspected patients, and retrospective external verification with clinical and simulated samples.

Population and setting

Serum samples obtained from 236 suspected patients, alongside 12 chikungunya-positive clinical samples and 5 simulated co-infection samples.

Main findings

The assay achieved high sensitivity and specificity for dengue and chikungunya detection, strong agreement with RT-qPCR, and accurately differentiated dengue serotypes without cross-reactivity.

Public-health relevance

The platform offers potential utility for point-of-care testing and outbreak surveillance in resource-limited settings.

Important limitations

This summary is limited to the supplied single-article abstract and metadata, and decision-grade interpretation requires consulting the original paper.

GIDS interpretation

This paper contributes technical methodology for multiplex pathogen detection and differential diagnosis, which may aid diagnostic capacity and surveillance frameworks in endemic or resource-constrained regions.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease Dengue
  • Disease Chikungunya
  • Topic Surveillance
  • Pathogen type Virus
  • Study setting Serum samples obtained from 236 suspected patients, alongside 12 chikungunya-positive clinical samples and 5 simulated co-infection samples.
  • Pathogen Dengue virus
  • Pathogen Chikungunya virus
  • Study design Journal article