Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesTuberculosis

Performance of Xpert MTB/RIF and acid-fast bacilli smear microscopy for the diagnosis of pulmonary tuberculosis using bronchoalveolar lavage samples in negative or sputum-scarce adults in Colombia: a retrospective diagnostic accuracy study

BMC Infectious Diseases ·

Vanessa Sabella-Jiménez, Valentina L. Sabella-Jiménez, Valentina Restrepo-Espinosa, Juanita Eljadue-Flórez, Claredit Valentina Gallardo-Castro, Andrea Alexandra Silvera, Carlos Otero-Herrera, Hugo Andrés Macareno Arroyo, Jorge Acosta-Reyes, Jorge Luis Quintero Barrios

DOI
10.1186/s12879-025-10856-z
PMID
40205580
PMCID
PMC11984154
OpenAlex
W4409309893
Integrity status
No known notices
Study design
Cross-sectional study
Publisher
Springer Science and Business Media LLC
Article type
journal-article

The paper situates BAL testing within TB diagnosis in a high-burden setting where sputum may be negative or limited. It highlights a trade-off: Xpert had stronger sensitivity and NPV, while smear microscopy retained attention because of speed, affordability and accessibility in resource-limited contexts.

01

Structured evidence summary

Research question

The study asked how accurately AFB smear microscopy and Xpert MTB/RIF identified pulmonary TB from bronchoalveolar lavage specimens in adults with negative or scarce sputum.

Study design

It used a retrospective, cross-sectional diagnostic accuracy design based on consecutive medical records from 2015 through 2023. Accuracy was summarized with sensitivity, specificity, predictive values and kappa statistics.

Population and setting

The analytic group comprised 283 adults among 701 screened records in a high-burden Colombian setting. They had suspected pulmonary TB, initially negative or limited sputum, and underwent bronchoscopy.

Main findings

For BAL specimens, Xpert MTB/RIF had 91.67% sensitivity, 90.09% specificity, 67.69% PPV and 97.95% NPV; smear microscopy had 39.22% sensitivity, 98.26% specificity, 83.33% PPV and 87.94% NPV. Kappa agreement was higher for Xpert MTB/RIF (0.7191) than for smear microscopy (0.472).

Public-health relevance

The paper situates BAL testing within TB diagnosis in a high-burden setting where sputum may be negative or limited. It highlights a trade-off: Xpert had stronger sensitivity and NPV, while smear microscopy retained attention because of speed, affordability and accessibility in resource-limited contexts.

Important limitations

The supplied abstract does not state explicit limitations. Because this is a retrospective, record-based diagnostic accuracy study and only the supplied article abstract/metadata were provided, the original paper is needed for decision-grade interpretation.

GIDS interpretation

In the supplied metadata, this is a peer-reviewed 2025 BMC Infectious Diseases article classified under tuberculosis, Colombia and diagnostics. Its role here is discoverable context on BAL-based diagnostic accuracy, not a connection to any live surveillance signal.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease Tuberculosis
  • Topic Diagnostics
  • Related Diagnostics
  • Location Colombia
  • Study setting The analytic group comprised 283 adults among 701 screened records in a high-burden Colombian setting. They had suspected pulmonary TB, initially negative or limited sputum, and underwent bronchoscopy.
  • Study design Cross-sectional study