Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesCOVID-19SARS

Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Infectivity by Viral Load, S Gene Variants and Demographic Factors, and the Utility of Lateral Flow Devices to Prevent Transmission

Clinical Infectious Diseases ·

Lennard Y W Lee, Stefan Rozmanowski, Matthew Pang, Andre Charlett, Charlotte Anderson, Gareth J Hughes, Matthew Barnard, Leon Peto, Richard Vipond, Alex Sienkiewicz, Susan Hopkins, John Bell, Derrick W Crook, Nick Gent, A Sarah Walker, Tim E A Peto, David W Eyre

DOI
10.1093/cid/ciab421
PMID
33972994
PMCID
PMC8136027
OpenAlex
W3163123530
Integrity status
No known notices
Study design
Journal article
Publisher
Oxford University Press (OUP)
Article type
journal-article

The findings help clarify transmission dynamics related to viral load, variant types, and settings, and indicate that effective lateral flow devices can identify a high percentage of cases associated with PCR-positive contacts.

01

Structured evidence summary

Research question

The study investigated how SARS-CoV-2 infectivity is related to viral load, S gene variants, and demographic elements, alongside evaluating the capability of lateral flow devices in preventing transmission.

Study design

An analysis combining testing and contact tracing data using multivariable logistic regression and simulation of lateral flow device performance.

Population and setting

The analysis utilized data from England spanning September 1, 2020, to February 28, 2021.

Main findings

Infectivity increased with higher index case viral loads and was elevated by approximately 50% with the B.1.1.7 infection. Transmission rates varied according to contact event types and age demographics, with household contacts showing the highest frequency of PCR-positive results.

Public-health relevance

The findings help clarify transmission dynamics related to viral load, variant types, and settings, and indicate that effective lateral flow devices can identify a high percentage of cases associated with PCR-positive contacts.

Important limitations

This summary relies exclusively on the supplied single-article abstract and metadata, requiring the original paper for decision-grade interpretation.

GIDS interpretation

This paper contributes contextual findings regarding transmission drivers and antigen test performance within outbreak investigation literature.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease COVID-19
  • Topic Outbreak investigation
  • Topic Transmission dynamics
  • Pathogen type Virus
  • Study setting The analysis utilized data from England spanning September 1, 2020, to February 28, 2021.
  • Pathogen SARS-CoV-2
  • Population Children
  • Study design Journal article