Posterior Oropharyngeal Saliva for the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)

Clinical Infectious Diseases ·

Sally Cheuk Ying Wong, Herman Tse, Hon Kei Siu, Tsz Shan Kwong, Man Yee Chu, Felix Yat Sun Yau, Ingrid Yu Ying Cheung, Cindy Wing Sze Tse, Kin Chiu Poon, Kwok Chi Cheung, Tak Chiu Wu, Johnny Wai Man Chan, Wah Cheuk, David Christopher Lung

DOI
10.1093/cid/ciaa797
PMID
32562544
PMCID
PMC7337706
OpenAlex
W3036901609
Integrity status
No known notices
Study design
Journal article
Publisher
Oxford University Press (OUP)
Article type
journal-article

The article is framed by pressure on healthcare systems and limits in diagnostic testing for timely case finding and isolation during COVID-19. It describes posterior oropharyngeal saliva as another sample type for SARS-CoV-2 detection.

01

Structured evidence summary

Research question

The study asked whether posterior oropharyngeal saliva could detect SARS-CoV-2 RNA in people diagnosed with or being evaluated for COVID-19.

Study design

The authors retrospectively searched testing records for respiratory samples and saliva specimens submitted for SARS-CoV-2 RNA assays from February 1 to April 15, 2020. They compared paired saliva and nasopharyngeal results for agreement and diagnostic performance.

Population and setting

The source group was patients with diagnosed or suspected COVID-19 whose respiratory specimens or saliva were tested during the stated period. The supplied evidence gives no country or facility details.

Main findings

Among 13,772 identified specimens, 2,130 were saliva and 8,438 were nasopharyngeal; among 229 same-day pairs, positivity was 61.5% for saliva and 53.3% for nasopharyngeal. Agreement was 76.0% overall, 65.4% for negatives, and 85.2% for positives, with positive agreement of 96.6% within 7 days of symptom onset versus 75.0% later. In 104 positive pairs, mean Cp difference was 0.26, nasopharyngeal samples generally had higher Cp values, and no significant time-associated difference between specimen types was reported.

Public-health relevance

The article is framed by pressure on healthcare systems and limits in diagnostic testing for timely case finding and isolation during COVID-19. It describes posterior oropharyngeal saliva as another sample type for SARS-CoV-2 detection.

Important limitations

No explicit limitations are stated in the supplied abstract. The reported retrospective record review and same-day paired subset limit what can be inferred here; this summary is limited to the supplied single-article abstract/metadata and requires the original paper for decision-grade interpretation.

GIDS interpretation

The supplied classifier places the paper under COVID-19 and diagnostics, and the abstract reports a specimen-comparison study for SARS-CoV-2 testing. This supports discoverability and context only; it should not be treated as evidence of a live surveillance signal.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease COVID-19
  • Topic Diagnostics
  • Related Diagnostics
  • Pathogen type Virus
  • Study setting The source group was patients with diagnosed or suspected COVID-19 whose respiratory specimens or saliva were tested during the stated period. The supplied evidence gives no country or facility details.
  • Pathogen SARS-CoV-2
  • Study design Journal article