Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesCOVID-19

Usability and Acceptability of Home-based Self-testing for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) Antibodies for Population Surveillance

Clinical Infectious Diseases ·

Christina Atchison, Philippa Pristerà, Emily Cooper, Vasiliki Papageorgiou, Rozlyn Redd, Maria Piggin, Barnaby Flower, Gianluca Fontana, Sutha Satkunarajah, Hutan Ashrafian, Anna Lawrence-Jones, Lenny Naar, Jennifer Chigwende, Steve Gibbard, Steven Riley, Ara Darzi, Paul Elliott, Deborah Ashby, Wendy Barclay, Graham S Cooke, Helen Ward

DOI
10.1093/cid/ciaa1178
PMID
—
PMCID
—
OpenAlex
W3158772406
Integrity status
No known notices
Study design
Journal article
Publisher
Oxford University Press (OUP)
Article type
journal-article

The article positions home lateral-flow antibody self-testing as a possible approach for seroprevalence surveys and population surveillance. Its relevance is framed through adult survey use, acceptability, usability, and reported agreement between participant and clinician result interpretation.

01

Structured evidence summary

Research question

The paper asks how acceptable and usable home self-testing for SARS-CoV-2 antibodies was when lateral-flow immunoassays were used in population-surveillance-oriented survey work.

Study design

The study combined public-involvement and pilot activities with 315 volunteers, using several feedback channels, then used that input to shape a representative survey of adults in England. Two lateral-flow assay types were sent to separate participant groups for home use and further feedback.

Population and setting

Pilot work involved 315 volunteers, and the survey arm involved adults in England. Tests were used at home by participants in the study groups.

Main findings

Pilot feedback suggested strong acceptance but identified problems with lancet and pipette handling, instructions, and judging results. In the national survey, 99.3% of LFIA1 and 98.4% of LFIA2 respondents tried the test, and 97.5% and 97.8% completed it. Valid results were 91.5% and 94.4%; participant-clinician agreement was kappa 0.72 for LFIA1 and 0.89 for LFIA2, with reported pipette difficulty at 17.7% for LFIA1 and blood-placement difficulty at 31.3% for LFIA2.

Public-health relevance

The article positions home lateral-flow antibody self-testing as a possible approach for seroprevalence surveys and population surveillance. Its relevance is framed through adult survey use, acceptability, usability, and reported agreement between participant and clinician result interpretation.

Important limitations

The abstract reports usability problems involving kit components, instructions, and result interpretation, with valid-result rates of 91.5% for LFIA1 and 94.4% for LFIA2. It does not include a dedicated study-limitations section, so this summary is limited to the supplied single-article abstract/metadata and needs the original paper for decision-grade interpretation.

GIDS interpretation

For discoverability, the article is tagged to SARS/COVID-19 and Surveillance, and its title and abstract concern home antibody self-testing for population surveillance or seroprevalence surveys. This supports contextual literature retrieval only; it does not indicate or verify a live surveillance signal.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease COVID-19
  • Topic Surveillance
  • Pathogen type Virus
  • Study setting Pilot work involved 315 volunteers, and the survey arm involved adults in England. Tests were used at home by participants in the study groups.
  • Pathogen SARS-CoV-2
  • Study design Journal article