Can Routine Laboratory Tests Discriminate between Severe Acute Respiratory Syndrome and Other Causes of Community‐Acquired Pneumonia?
Clinical Infectious Diseases ·
- DOI
- 10.1086/428577
- PMID
- 15791504
- PMCID
- PMC7107805
- OpenAlex
- W2118953259
- Integrity status
- No known notices
- Study design
- Journal article
- Publisher
- Oxford University Press (OUP)
- Article type
- journal-article
The findings bear on the use of routine laboratory measures in SARS diagnosis and case definitions. In this comparison, the tests did not provide a reliable basis for distinguishing SARS from community-acquired pneumonia.
Structured evidence summary
Research question
The study assessed whether routine laboratory measurements at hospital admission could distinguish SARS cases from community-acquired pneumonia cases.
Study design
The authors compared data from two databases and age-matched SARS patients to community-acquired pneumonia patients. They used receiver operating characteristic curves to evaluate individual laboratory measures and pairs of tests.
Population and setting
The comparison included 144 patients with SARS from the 2003 Toronto outbreak and 8,044 patients with community-acquired pneumonia from Edmonton, Canada.
Main findings
Most tested laboratory measures had fair-to-poor discriminatory performance; the absolute neutrophil count had an AUC of 0.80, but no cutoff provided reasonable sensitivity or specificity. Combining two tests did not significantly outperform the absolute neutrophil count alone. The authors concluded that routine laboratory tests, including lymphocyte count, should not be used to diagnose SARS or added to its case definitions, and that the neutrophil count warrants further assessment.
Public-health relevance
The findings bear on the use of routine laboratory measures in SARS diagnosis and case definitions. In this comparison, the tests did not provide a reliable basis for distinguishing SARS from community-acquired pneumonia.
Important limitations
The abstract reports that no absolute neutrophil count cutoff achieved reasonable sensitivity or specificity. This summary is limited to the supplied single-article abstract and metadata; the original paper is needed for decision-grade interpretation.
GIDS interpretation
The article is discoverable in the supplied metadata under SARS, Canada, diagnostics, and outbreak investigation. The abstract concerns the 2003 SARS outbreak in Toronto; these classifications provide context and do not establish any connection to a current surveillance signal.
Related GIDS surveillance
Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.
Evidence relationships
- Disease SARS
- Topic Diagnostics
- Topic Outbreak investigation
- Related Diagnostics
- Pathogen type Virus
- Study setting The comparison included 144 patients with SARS from the 2003 Toronto outbreak and 8,044 patients with community-acquired pneumonia from Edmonton, Canada.
- Pathogen SARS-CoV-2
- Study design Journal article