Nosocomial Transmission of Hepatitis B Virus Associated with the Use of a Spring-Loaded Finger-Stick Device
New England Journal of Medicine ·
- DOI
- 10.1056/nejm199203123261101
- PMID
- 1738376
- PMCID
- —
- OpenAlex
- W2337624352
- Integrity status
- No known notices
- Study design
- Cohort study
- Publisher
- Massachusetts Medical Society
- Article type
- journal-article
The findings support careful use of finger-stick devices and strict adherence to precautions against blood contamination as measures that may reduce transmission of blood-borne pathogens in hospitals.
Structured evidence summary
Research question
The study investigated the source of acute hepatitis B virus infections clustered among hospitalized patients with diabetes, focusing on finger-stick blood sampling with a spring-loaded lancet device.
Study design
The investigators used a retrospective cohort study of patients with diabetes and a case-control study of nondiabetic patients and controls. They also reviewed relevant nursing procedures.
Population and setting
The setting was a single California hospital ward where 26 patients developed acute hepatitis B between June 1989 and March 1990; 23 had diabetes. The cohort comprised 72 patients with diabetes admitted during 1989, while the case-control comparison included three nondiabetic cases and 20 nondiabetic controls.
Main findings
Finger-stick sampling was associated with higher observed HBV attack rates among patients with diabetes (42% versus 0%; P=0.08) and with a dose-response pattern according to the number of finger sticks (P=0.002). All three nondiabetic cases had undergone finger-stick sampling, compared with none of the controls (P=0.0006); procedure review suggested that device-platform contamination was the likely transmission mechanism.
Public-health relevance
The findings support careful use of finger-stick devices and strict adherence to precautions against blood contamination as measures that may reduce transmission of blood-borne pathogens in hospitals.
Important limitations
The evidence is limited to the supplied single-article abstract and metadata, which do not provide enough methodological detail for decision-grade interpretation. The nondiabetic case-control comparison was small, and the retrospective cohort finding for the overall attack-rate difference was not statistically significant at the reported threshold.
GIDS interpretation
For discoverability, the paper is relevant to hepatitis B transmission dynamics and nosocomial infection associated with reusable finger-stick equipment. The supplied record is a peer-reviewed journal article; it does not constitute confirmation from a live surveillance system.
Related GIDS surveillance
Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.
Evidence relationships
- Disease Hepatitis B
- Topic Transmission dynamics
- Pathogen type Virus
- Study setting The setting was a single California hospital ward where 26 patients developed acute hepatitis B between June 1989 and March 1990; 23 had diabetes. The cohort comprised 72 patients with diabetes admitted during 1989, while the case-control c
- Study design Cohort study