Global search

Find data and evidence

Type at least 2 characters. Use arrow keys to review and Enter to open.

Peer reviewedOpen accessNo known noticesCOVID-19

Assessing a novel, lab-free, point-of-care test for SARS-CoV-2 (CovidNudge): a diagnostic accuracy study

The Lancet Microbe ·

Malick M Gibani, Christofer Toumazou, Mohammadreza Sohbati, Rashmita Sahoo, Maria Karvela, Tsz-Kin Hon, Sara De Mateo, Alison Burdett, K Y Felice Leung, Jake Barnett, Arman Orbeladze, Song Luan, Stavros Pournias, Jiayang Sun, Barney Flower, Judith Bedzo-Nutakor, Maisarah Amran, Rachael Quinlan, Keira Skolimowska, Carolina Herrera, Aileen Rowan, Anjna Badhan, Robert Klaber, Gary Davies, David Muir, Paul Randell, Derrick Crook, Graham P Taylor, Wendy Barclay, Nabeela Mughal, Luke S P Moore, Katie Jeffery, Graham S Cooke

DOI
10.1016/s2666-5247(20)30121-x
PMID
32964211
PMCID
PMC7498257
OpenAlex
W3084792233
Integrity status
No known notices
Study design
Journal article
Publisher
Elsevier BV
Article type
journal-article

The abstract indicates that a rapid SARS-CoV-2 test requiring no laboratory handling or sample pre-processing could support faster clinical-care and testing-programme decisions. This is presented as a potential operational use rather than evidence of effects on health outcomes or surveillance performance.

01

Structured evidence summary

Research question

The study assessed the sensitivity and specificity of the lab-free, point-of-care CovidNudge real-time RT-PCR test for detecting SARS-CoV-2 compared with laboratory-based RT-PCR.

Study design

This was a diagnostic accuracy study using paired nasopharyngeal swabs tested in parallel with the CovidNudge platform and standard laboratory RT-PCR. The primary analysis compared the two methods’ sensitivity and specificity.

Population and setting

Between April and May 2020, 386 paired samples were collected in three hospitals in London and Oxford, UK. Participants included self-referred health-care workers with suspected COVID-19, emergency-department patients with suspected COVID-19, and hospital inpatients with or without suspected COVID-19.

Main findings

Among 386 paired samples, 67 were positive on CovidNudge and 71 on laboratory RT-PCR. Overall sensitivity was 94% (95% CI 86–98) and specificity was 100% (99–100); reported sensitivity varied by participant group, while specificity was consistent across groups.

Public-health relevance

The abstract indicates that a rapid SARS-CoV-2 test requiring no laboratory handling or sample pre-processing could support faster clinical-care and testing-programme decisions. This is presented as a potential operational use rather than evidence of effects on health outcomes or surveillance performance.

Important limitations

The supplied abstract does not report explicit study limitations. This summary is limited to the single supplied article abstract and metadata; the original paper is required for decision-grade assessment of study limitations and applicability.

GIDS interpretation

The article is discoverable in a COVID-19, United Kingdom, and diagnostics context. Its evidence concerns diagnostic-test accuracy and does not establish or confirm a live surveillance signal.

02

Related GIDS surveillance

Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.

03

Evidence relationships

  • Disease COVID-19
  • Topic Antimicrobial resistance
  • Topic Diagnostics
  • Related Diagnostics
  • Pathogen type Virus
  • Study setting Between April and May 2020, 386 paired samples were collected in three hospitals in London and Oxford, UK. Participants included self-referred health-care workers with suspected COVID-19, emergency-department patients with suspected COVID-1
  • Pathogen SARS-CoV-2
  • Population Healthcare workers
  • Study design Journal article