The laboratory reality of multiplex respiratory viral detection: findings from a comprehensive external quality assessment study in China
International Journal of Infectious Diseases ·
- DOI
- 10.1016/j.ijid.2026.108841
- PMID
- 42214661
- PMCID
- —
- OpenAlex
- W7162647142
- Integrity status
- No known notices
- Study design
- Journal article
- Publisher
- Elsevier BV
- Article type
- journal-article
The findings highlight both the maturity of multiplex viral testing technology and persistent quality challenges. The occurrence of false-negatives and false-positives indicates ongoing needs for assay optimization, enhanced laboratory quality management, and greater clinician awareness of test limitations.
Structured evidence summary
Research question
The study assessed the capability of laboratories in China to perform multiplex nucleic acid amplification tests for respiratory viral detection through a comprehensive external quality assessment.
Study design
This was a large-scale external quality assessment study in which laboratories performing multiplex viral nucleic acid tests were publicly recruited and provided with a reference panel to evaluate testing performance. Multivariate analysis was conducted on results and methodological data to identify error sources.
Population and setting
The study enrolled 914 laboratories in China that perform multiplex respiratory viral nucleic acid amplification tests.
Main findings
Overall concordance was 81.6% among participating laboratories. False-positives were concentrated in 13 laboratories, suggesting contamination, while false-negatives were more common and primarily occurred in low viral load samples. Independent risk factors for false-negatives included capillary electrophoresis-based multiplex PCR, a specific commercial kit, laboratory-developed tests, and suboptimal laboratory performance.
Public-health relevance
The findings highlight both the maturity of multiplex viral testing technology and persistent quality challenges. The occurrence of false-negatives and false-positives indicates ongoing needs for assay optimization, enhanced laboratory quality management, and greater clinician awareness of test limitations.
Important limitations
This summary is limited to the supplied single-article abstract and metadata and requires review of the original paper for decision-grade interpretation of study methodology, detailed statistical analyses, and complete contextual findings.
GIDS interpretation
The article was identified through classifier links to influenza, China, and diagnostics topics, providing context on laboratory diagnostic capacity for respiratory pathogens in a major global region. This reflects methodological quality assessment rather than connection to active disease surveillance signals.
Related GIDS surveillance
- Influenza China
Literature links provide context, not evidence of a signal’s cause. Disease-only matches do not establish geographic relevance.
Evidence relationships
- Disease Influenza
- Disease Respiratory syncytial virus infection (RSV)
- Topic Diagnostics
- Related Diagnostics
- Pathogen type Virus
- Location China
- Study setting The study enrolled 914 laboratories in China that perform multiplex respiratory viral nucleic acid amplification tests.
- Study design Journal article